Robinair high tank pressure

Jul 4, 2021 · From https://www.justanswer.com/ythiJustAnswer Customer: MY ROBINAIR MODEL #34788 IS STUCK IN A HIGH PRESSURE RESET MODE AND WILL NOT WORK.JustAnswer Custome... .

Locate the high pressure switch near the compressor (a cylindrical device piped into the refrigeration system with two wires a red button on the top). Push in the button to reset. Push the rocker switch to restart the unit. The thermostat will be flashing temperature with the ! next to it (if the cellar has warmed up past 64F).ROBINAIR.COM 800.533.6127 Recover, Recycle, Recharge Machine for R-134a A/C Systems ... Do not use in open air in case of rain or high humidity. Wear gloves. Wear protection goggles. Alternating voltage. ... use only type-approved refillable containers that have pressure relief valves. HOSES CAN CONTAIN LIQUID REFRIGERANT UNDER …

Did you know?

down when the storage tank reaches 80% capacity if the float cable is used correctly. Use only Robinair tank p/n 17990 with this machine. Shut-off Switch This unit has an internal, high-pressure, shut-off switch. If system pressure rises above 435 psi, the unit shuts off. The shut-off switch automatically resets itself after Robinair Advanced R134A 35 581137 REV D Troubleshooting Display Cause Solution AIR PURGE ERROR DUE TO EXCESSIVE PURGE TIME Possible poor sensor contact with tank Ve...Robinair 34788ni = High Tank Pressure Tool & Equipment Posted on Forum 7/15/2017 5 Reply Hey Guys, a good start on Saturday morning! brand new 34788ni used once before this morning. Had three AC jobs scheduled for the day, recovered one problem, hooked up to the second one and started recovering and walked away a little bit.Price $22.68. Add To Cart. 11794 Robinair Low Side Compound Refrigerant Manifold Gauge R22/134a -30 To 120 Psi/Bar. Low Side Universal Replacement Compound Gauge -30" to 120 Psi/Bar, Psi/kPa pressure readings, R-22 and R-134a temperature readings in degrees Celsius, Replaces 11692.

Robinair 34788ni high tank pressure Robinair 34788ni = high tank pressure Posted to Tool & Equipment Forum on 7/15/2017 5 Replies Hey guys, good start to a saturday morning! brand new 34788ni used once before this morning. had 3 ac jobs scheduled for the day, recovered one no problem, hooked to the second one and started recover and …To calibrate the scale on Robinair 34288, follow these steps: Turn off the machine and make sure that the scale is empty. Press and hold the "Weight" button for three seconds until "CAL" appears on the display. Place a weight of known mass (such as a 50-pound weight) onto the scale and press the "Weight" button. i have a robinair a/c machine 34788-h that will not work anymore keeps sending error message pressure too high . DO YOU KNOW WHAT PART IS MOST …Traffic on JustAnswer rose 14 percent...and had nearly 400,000 page views in 30 days...inquiries related to stress, high blood pressure, drinking and heart pain jumped 33 percent. Tory Johnson, GMA Workplace Contributor, discusses work-from-home jobs, such as JustAnswer in which verified Experts answer people’s questions.pressure of Recovery Tank cylinder. 5. m Warning: DO NOT: Exceed the working pres- sure of each cylinder. Recovery cylinders are designed for different pressures. Your 25176B is not supplied with a recovery tank, it requires the use of tanks with a minimum of 350 psi working pressure and ROBINAIR strongly recommends the use of 400 psi tanks.

Set the beeper tone to high (Beeper 1), low (Beeper 2) or none (Mute). Service Menu Robinair service center use only. Hose Flush Flushes any residual oil from the unit for service of vehicles with different oils. Display Tank Info Displays internal storage vessel (ISV) pressure and temperature. Use to check the ISV for excessive pressure. Stop ...source tank. (For R-134a, use quick-coupler adapter No. 116121; for R-12, use the 6" yellow adapter No. 710778. Both are included with unit.) NOTE: If using a refillable tank, install the tank upside down, and connect the low-side service hose to the vapor valve. 8. Open the tank valve and invert the tank. Press START when finished. 9. ….

Reader Q&A - also see RECOMMENDED ARTICLES & FAQs. Robinair high tank pressure. Possible cause: Not clear robinair high tank pressure.

1. Check for pressure on gauges. 2. Checks the service couplers are open. 3. Check tank valve are open. 4. Check that the compressor is running. 5. Check tank pressure and purge tank if needed. Air purge in maintenance menu. 6. Close liquid ball valve on tank filter. If recovery then happens the charge . solenoid valve has dirt in valve.• Over pressure valves. • A maximum pressure switch stops the compressor when excessive pressure is sensed. WARNING: Tampering with these protective devices could result in serious injury . Refrigerant Tank Test Official records and recurring tests necessary for pressurized instruments are governed by laws and/or national

We stock many common replacement parts including High / Low Side Couplers, Hoses, Filters, Tank Fill Adapters, Oil Bottles, Solenoids, Dust Covers and more. Products search. Parts & Breakdowns. ... Home Replacement Parts A/C Machines Robinair 34788NI Parts. Robinair 34788NI Parts. 16103 - Flat-Free Wheel quantity. 16103 - Flat-Free WheelFor Robinair service center use only. Menu Choice: Calibration Check Use to verify internal scale calibration. Refer to instructions in Maintenance section under Scale Calibration Check. Menu Choice: Adjust Tank Fill Lvl During the tank refill process, the unit stops refilling when it reaches the pre-set amount of refrigerant in the internal

tyrone jr source tank. (For R-134a, use quick-coupler adapter No. 116121; for R-12, use the 6" yellow adapter No. 710778. Both are included with unit.) NOTE: If using a refillable tank, install the tank upside down, and connect the low-side service hose to the vapor valve. 8. Open the tank valve and invert the tank. Press START when finished. 9. behavioral psychology phd programskansas state roster basketball i have a robinair a/c machine 34788-h that will not work anymore keeps sending error message pressure too high . DO YOU KNOW WHAT PART IS MOST … okstate student all sports pass Some mixtures of air and refrigerant have been shown to be combustible at elevated pressures. These mixtures, if ignited, may cause injury or property damage. TO PREVENT CROSS-CONTAMINATION, USE THIS UNIT WITH R-134A REFRIGERANT ONLY. The unit is designed to recover, recycle, and recharge only R-134a refrigerant. Refrigerant Tank. 30 lb. tank, 1/4" fittings (25150, 25175, 25200B, 34234, 34300-2K, 34800 series). Documents; Nitrogen SDS for empty refrigerant tanks. Contact Us; Catalogs; Media Downloads; Invent with Robinair; Service Center Application Form; Customer Service / Tech Support 1-800-533-6127. [email protected] . Bosch Automotive Service ... south jam volleyballdiscord nitro pfpsstarbucks union hours Here are the steps to adjust the contrast on the Robinair 34788: Turn on the machine and wait for the display to fully light up. Press and hold the "Enter" and "Clear" buttons simultaneously for three seconds. The display will show "Contrast" and the current contrast setting. Use the "+" and "-" buttons to adjust the contrast to your desired level.Robinair introduces its next innovation, the 34788NI-H, featuring an industry leading 98.5% recovery efficiency for standard and hybrid vehicles and fully automatic function. The Robinair 34788NI-H machines recover, recycle, evacuate, leak-test and recharge R-134a with improved 98.5% efficiency – unmatched by any competitor. kgs picture The unit includes a 1.5 cfm (42 l/m) Robinair high vacuum pump for fast, thorough evacuation. The compressor pulls the A/C system to 0 psig, then works in series with the vacuum pump to achieve highly efficient recovery and immediate recharge. Industry-leading efficiency and more accurate service 16-70 ROBINAIR.COM 800.533.6127 Specifications Operating Temperature 32° - 120°F (0°-50°C) Filter Capacity 150 lb (75kg), spin-on type Storage Temperature 0 to 150°F (-18 to 66°C) Internal Cylinder 30 lb. DOT Recovery Performance >95% at 70 to 75° F (21 to 24°C) <30 minutes Operating Voltage … i94 admit until datestephen r mcallistercommunity needs assesment Follow these steps to replace the high pressure cut-out switch on your unit. 1. Close the tank valves and depressurize the unit. 2. Turn off the MAIN POWER switch, and unplug the unit from the power source. 3. Remove the panel(s) or shroud to access the manifold block. 4. Disconnect the wires from the high pressure cutout switch. 5.124015 Robinair High Pressure Wire Harness 348002K Post 30000 Serial Number. Connects high pressure switch to main board. Board connection P11. Price $11.95 . 13172 Robinair Filter Pump Oil Maintenance Kit With 34724 Filter ...